logo
Guangzhou Sande Electric Co.,Ltd.
Email Sales01@sande-elec.com TEL: 86--18620505228
Home > Products > CNC Circuit Board >
Original Siemens 430/440/S120 Inverter/Converter Power Supply Board C98043-A7600-L4 C98043A7600L4 C98O43-A76OO-L4
  • Original Siemens 430/440/S120 Inverter/Converter Power Supply Board C98043-A7600-L4    C98043A7600L4    C98O43-A76OO-L4

Original Siemens 430/440/S120 Inverter/Converter Power Supply Board C98043-A7600-L4 C98043A7600L4 C98O43-A76OO-L4

Place of Origin Germany
Brand Name SIEMENS
Certification CE RoHS
Model Number C98043-A7600-L4
Product Details
Condition:
New Factory Seal(NFS)
Item No.:
C98043-A7600-L4
Origin:
Germany
Highlight: 

siemens fanuc pcb board

,

siemens cnc circuit board

,

power fanuc pcb board

Payment & Shipping Terms
Minimum Order Quantity
1 pcs
Packaging Details
original packing
Delivery Time
0-3 days
Payment Terms
T/T,PayPal,Western Union
Supply Ability
100 pcs/day
Product Description

C98043-A7600-L4 | Siemens Inverter Power Board — C98043-A7600 Series / L4 Revision / Drive Inverter PCB Spare


C98043-A7600 — A Multi-Revision Inverter Power Board Family

The C98043-A7600-L4 is the L4 revision inverter power board within the Siemens C98043-A7600 series — a confirmed family of inverter power boards spanning at least three hardware revision levels:


Revision Board
L3 C98043-A7600-L3 (previous revision)
L4 C98043-A7600-L4 — this product
L5 C98043-A7600-L5 (43kW, 380–480V AC)


In Siemens' C98043 spare parts system, the L-number represents the hardware revision level — each L-revision may incorporate component changes, layout improvements, or functional updates relative to the preceding level. The C98043-A7600 family progresses from L3 through L5, with the L4 revision positioned between the L3 and the L5 which carries confirmed 43kW / 380–480V specifications.


Key Product Information

Parameter Value
Part Number C98043-A7600-L4
Series C98043-A7600
Revision L4
Type Inverter Power Board
Application Siemens inverter drive

Inverter Power Board Role in Drive Systems

The C98043-A7600 inverter power boards serve the power-stage interface function within Siemens drive systems — connecting the control electronics to the actual switching transistors that produce the variable-frequency output:

Gate drive interface: The inverter power board routes PWM switching commands from the drive's control circuit to the transistor gate inputs — providing the current amplification and isolation needed to switch power transistors reliably.


Current feedback path: Armature or motor current measured by current sensors in the power stage is conditioned and routed back to the control electronics through the inverter power board — providing the real-time current measurement that the drive's closed-loop current control requires.

Fault signal routing: Transistor fault signals — overcurrent, desaturation, over-temperature — detected at the power stage are collected by the inverter power board and forwarded to the drive's protection circuitry for appropriate shutdown response.


Application Scenarios

Inverter power board fault — C98043-A7600-L4: A Siemens drive system develops power-stage level faults traceable to the inverter power board. The C98043-A7600-L4 is identified from its label. Replacement restores correct power-stage interface function.

Drive overhaul: A production facility maintaining Siemens inverter drive equipment includes C98043-A7600-L4 in a planned drive board renewal programme.


FAQ

Q1: How do I confirm C98043-A7600-L4 (L4) versus L3 or L5 is correct for my drive?

Read the installed board's full part number label — including the L-number. If it reads C98043-A7600-L4, the L4 revision is confirmed. The L-revision must match the installed board. Different revisions may have hardware differences that prevent safe substitution. The applicable drive's maintenance manual or spare parts list confirms which L-revision is required.


Q2: Can C98043-A7600-L4 be substituted for C98043-A7600-L3 or L5?

Not without confirmation. Consecutive L-revisions in the C98043-A7600 family may be upward-compatible or may involve hardware changes that prevent cross-revision substitution. Confirm compatibility from the drive's maintenance documentation or Siemens' spare parts compatibility information before substituting a different L-revision.


Q3: What drive fault symptoms indicate a C98043-A7600-L4 inverter power board failure?

Inverter power board failures produce power-stage alarms — phase overcurrent faults occurring at low or zero load current during drive enable, asymmetric motor current distribution, or current measurement errors. These differ from control-level faults (which produce software or parameter alarms) and from motor faults (which occur at load). If the power transistors are undamaged but inverter alarms persist, the power board is the diagnostic priority.


Q4: What ESD and safety precautions apply when handling C98043-A7600-L4?

Isolate and lock out the drive mains supply. Verify the DC bus has discharged below 50V before accessing internal components — the bus retains hazardous voltage after mains removal. Handle C98043-A7600-L4 with an anti-static wrist strap on an ESD-safe surface.