logo
Guangzhou Sande Electric Co.,Ltd.
Email Sales01@sande-elec.com TEL: 86--18620505228
Home > Products > CNC Circuit Board >
Siemens 430/18.5kw/440/15kw Inverter/Converter Driver Board /Power Amplifier Board A5E00909986 A5EOO9O9986
  • Siemens 430/18.5kw/440/15kw Inverter/Converter Driver Board /Power Amplifier Board A5E00909986    A5EOO9O9986

Siemens 430/18.5kw/440/15kw Inverter/Converter Driver Board /Power Amplifier Board A5E00909986 A5EOO9O9986

Place of Origin Germany
Brand Name SIEMENS
Certification CE RoHS
Model Number A5E00909986
Product Details
Condition:
New Factory Seal(NFS)
Item No.:
A5E00909986
Origin:
Germany
Highlight: 

siemens fanuc pcb board

,

siemens cnc circuit board

,

power fanuc pcb board

Payment & Shipping Terms
Minimum Order Quantity
1 pcs
Packaging Details
original packing
Delivery Time
0-3 days
Payment Terms
Western Union,L/C,T/T
Supply Ability
10000pcs/day
Product Description

A5E00909986 | Siemens A5E Series Converter PC Board — Industrial Drive and Converter Spare Part


A5E00909986 — Converter PC Board in the Siemens Spare Parts System

The A5E00909986 is a Siemens A5E-series converter PC board — a printed circuit board serving a defined control, interface, or drive function within a Siemens industrial converter system.

The A5E part number series spans Siemens' drive and automation spare parts — covering boards from SINAMICS S120 motor modules and power blocks through MICROMASTER converter boards and a wide range of other drive and automation PCBs. The A5E00909986 at the 909xxx number range sits in the upper portion of the confirmed A5E000xxxxxx numbering — reflecting a specific product generation within the A5E converter board catalogue.


The "CONVERTER / PC BOARD" description confirms A5E00909986 as an internal PCB within a Siemens converter — a PCB that provides control, interface, gate drive, or measurement functions within the converter's electronic architecture.


Key Product Information

Parameter Value
Part Number A5E00909986
Series A5E (Siemens spare parts)
Type Converter PC Board
Application Siemens industrial converter

Converter PC Boards in Siemens Drive Architecture

Converter PC boards in Siemens drive and automation systems serve defined functions — typically one or more of:

Gate drive and trigger functions: Providing the switching commands to the power transistors (IGBT or thyristor) that generate the converter's output.

Measurement and feedback: Processing current and voltage signals from the power stage — providing the control electronics with real-time measurement data for closed-loop regulation.


Control and regulation: Executing the converter's speed or frequency control algorithms — receiving setpoint commands and generating the appropriate switching pattern to achieve the commanded output.

Communication interface: Connecting the converter's power electronics to fieldbus or serial communication channels — enabling remote operation and monitoring.


Application Scenarios

Converter PC board fault: A Siemens converter system develops faults traceable to the A5E00909986 board. The board is identified from its part number label inside the converter unit. Replacement restores converter operation.

Planned converter maintenance: A facility maintaining Siemens converter equipment stocks A5E00909986 as a spare for the specific converter in which it is installed.


FAQ

Q1: How do I confirm A5E00909986 is the correct board for my Siemens converter?

Read the part number from the board's label inside the converter. If it reads A5E00909986, this is the confirmed replacement. Cross-reference with the converter's maintenance manual and spare parts list to confirm the board's position and function.


Q2: What types of converter faults indicate an A5E00909986 PC board failure?

Converter PC board faults typically produce: control-level alarms (software or parameter errors), gate drive failures (inverter or thyristor firing alarms), measurement anomalies (incorrect current or voltage readings), or communication faults (fieldbus or serial interface errors). The specific fault pattern indicates which board function has failed. If the converter's power components are verified as healthy but alarms persist on enabling, the PC board is the diagnostic focus.


Q3: Does replacing A5E00909986 affect converter parameters?

This depends on the board's specific function. Control boards that store configuration data require parameter backup before replacement and restoration after. Interface or gate drive boards typically do not store drive parameters. Confirm from the applicable Siemens maintenance documentation before proceeding.


Q4: What ESD and safety precautions apply when handling A5E00909986?

Isolate and lock out the converter mains supply. Verify the DC bus is below 50V after the discharge interval before internal access. Handle A5E00909986 with a grounded anti-static wrist strap on an ESD-safe surface.



Contact Us at Any Time

+86 18620505228
10/F,Jia Yue Building, Chebei Road,Tianhe district,Guangzhou ,China
Send your inquiry directly to us