logo
Send Message
Guangzhou Sande Electric Co.,Ltd.
Email Sales01@sande-elec.com TEL: 86--18620505228
Home > Products > CNC Circuit Board >
EB1 Terminal Board 6SX7010-0KB00 6SE7090-0XX84-0KB0 6SX70100KB00 6SE70900XX840KB0 6SX7O1O-OKBOO 6SE7O9O-OXX84-OKBO
  • EB1 Terminal Board 6SX7010-0KB00 6SE7090-0XX84-0KB0    6SX70100KB00 6SE70900XX840KB0    6SX7O1O-OKBOO 6SE7O9O-OXX84-OKBO

EB1 Terminal Board 6SX7010-0KB00 6SE7090-0XX84-0KB0 6SX70100KB00 6SE70900XX840KB0 6SX7O1O-OKBOO 6SE7O9O-OXX84-OKBO

Place of Origin Germany
Brand Name SIEMENS
Certification CE ROHS
Model Number 6SX7010-0KB00 6SE7090-0XX84-0KB0
Product Details
Condition:
New Factory Seal(NFS)
Item No.:
6SX7010-0KB00 6SE7090-0XX84-0KB0
Origin:
Germany
Highlight: 

CNC circuit board terminal block

,

EB1 terminal board 6SX7010

,

6SE7090 circuit board replacement

Payment & Shipping Terms
Minimum Order Quantity
1 pcs
Packaging Details
original packing
Delivery Time
0-3 days
Payment Terms
T/T,PayPal,Western Union
Supply Ability
100 pcs/day
Product Description

Siemens 6SX7010-0KB00 | SIMOVERT MASTERDRIVES EB1 Terminal Expansion Module — Retrofit Kit with Connectors X480 and X481

Part Number (Kit): 6SX7010-0KB00

Board Order Number: 6SE7090-0XX84-0KB0

Manufacturer: Siemens AG (Germany) 


Adding I/O to the Drive

The 6SX7010-0KB00 is the EB1 Terminal Expansion Module retrofit kit for SIMOVERT MASTERDRIVES MC and VC drives. It adds a first block of analogue and digital I/O terminals — connectors X480 and X481 — to the drive's electronics box. This expansion is used when the drive's base CUD terminal set cannot accommodate all the I/O signals needed by the application.


Signals connected to the EB1's X480 and X481 connectors become part of the drive's BICO parameter structure — the same system used for base I/O. No external signal converters or additional hardware are needed. The EB1 slots into any available option slot (A through G) and is auto-detected at power-up.


The complementary EB2 module (6SX7010-0KC00) uses connectors X490 and X491 for a second I/O expansion. Both EB1 and EB2 can be fitted simultaneously in separate slots. The kit is supplied with both connectors and installation instructions, making it a complete field-installation package.


Kit vs Board-Only Reference

Order Ref Contents
6SX7010-0KB00 EB1 board + X480/X481 connectors + instructions (retrofit kit)
6SE7090-0XX84-0KB0 Board only — no connectors

For field replacement or new installation, the 6SX7010-0KB00 kit is the recommended order reference.


Key Specifications

Parameter Value
Kit No. 6SX7010-0KB00
Board No. 6SE7090-0XX84-0KB0
Connectors X480, X481
Platform SIMOVERT MASTERDRIVES MC/VC
Slot Range A–G
Discontinued September 2020

FAQ

Q1: Does the EB1 need to be enabled in parameters after installation?

The EB1 is auto-detected at power-up when correctly seated. No parameter is needed to "enable" the board itself. However, the BICO parameterisation must be configured to route signals between the EB1's X480/X481 terminals and the drive's internal functions — this is standard SIMOVERT MASTERDRIVES parameterisation.



Q2: Can EB1 and EB2 be installed in the same drive at the same time?

Yes. EB1 (X480/X481) and EB2 (X490/X491) are independent modules assigned to different connectors and different option slots. Both can be fitted simultaneously, provided two available slots exist. Check available slots before ordering both modules.



Q3: The 6SX7010-0KB00 was discontinued in September 2020. Is it still available?

The industrial aftermarket is the primary supply channel post-discontinuation. Specialist SIMOVERT MASTERDRIVES spare parts dealers hold exchange stock for both the EB1 kit and the board-only variant.



Q4: Can the EB1 analogue outputs be used to send actual-value signals — speed, current, torque — to an external controller?

Yes. Any drive measurement variable accessible through BICO can be assigned to an EB1 analogue output channel. The output range — typically ±10V — is configured through the relevant EB1 output parameter.



Q5: The EB1 is installed but the drive shows no signals from X480 or X481. What should be checked first?

Confirm the board is fully seated in its option slot — a partial connection prevents detection. Verify the slot assignment does not conflict with another module's Z-option setting. If seating and slot assignment are correct and the board is still unrecognised, check whether the drive's installed software version supports the EB1.

Contact Us at Any Time

+86 18620505228
10/F,Jia Yue Building, Chebei Road,Tianhe district,Guangzhou,China