logo
Guangzhou Sande Electric Co.,Ltd.
Email Sales01@sande-elec.com TEL: 86--18620505228
Home > Products > High Power IGBT Module >
New Siemens 6SY7000-0AD50 IGBT Module In Box 6SY70000AD50
  • New Siemens 6SY7000-0AD50 IGBT Module In Box 6SY70000AD50

New Siemens 6SY7000-0AD50 IGBT Module In Box 6SY70000AD50

Place of Origin Germany
Brand Name Siemens
Certification CE RoHS
Model Number 6SY7000-0AD50
Product Details
Condition:
New Factory Seal (NFS)
Item No.:
6SY70000AD50
Origin:
Germany
Highlight: 

Siemens 6SY7000 IGBT module

,

High power IGBT module with warranty

,

6SY7000-0AD50 IGBT module in box

Payment & Shipping Terms
Minimum Order Quantity
1 pcs
Packaging Details
Original packing
Delivery Time
0-3 days
Payment Terms
T/T,PayPal,Western Union
Supply Ability
100 pcs/day
Product Description

6SY7000-0AD50 | Siemens SIMOVERT MASTERDRIVES IGBT Module — FZ1800R16KF4 / 1800A / 1600V / Generator Side Inverter


FZ1800R16KF4 — The IGBT at the Heart of 6SY7000-0AD50

The 6SY7000-0AD50 is Siemens' spare part designation for the Infineon FZ1800R16KF4 IGBT module as fitted in SIMOVERT MASTERDRIVES large drive systems. The FZ1800R16KF4 is an Infineon EconoPACK+ format IGBT module:


FZ designation: "FZ" identifies the Infineon EconoPACK+ housing with press-fit contact technology and integrated freewheeling diodes — the generation of IGBT module that preceded the later EconoPACK+4 format.


1800A collector current: The module's continuous on-state current capability at the rated case temperature. At 1800A, this is one of the highest-current standard IGBT modules in the EconoPACK+ format — suited to the highest-power classes of SIMOVERT MASTERDRIVES installations.


1600V blocking voltage: The collector-emitter breakdown voltage exceeds 1600V — providing the 2× safety margin required over the ~800V DC bus of a standard 480V AC drive system, and covering the higher DC bus voltages of 660–690V AC supply installations.


Key Specifications

Parameter Value
Part Number 6SY7000-0AD50
IGBT Module FZ1800R16KF4 (Infineon)
Collector Current 1800A
Blocking Voltage 1600V
Application SIMOVERT MASTERDRIVES
Position Generator side inverter
Type IGBT-Transistor Module



6SY7000 Series — SIMOVERT MASTERDRIVES IGBT Spare Parts

The 6SY7000 catalogue series is Siemens' spare parts designation range for IGBT and power semiconductor modules used inside SIMOVERT MASTERDRIVES chassis drives. The 6SY prefix identifies these as SIMOVERT spare parts — not standalone IGBT modules for general market distribution, but units pre-configured, tested, and catalogued for the specific MASTERDRIVES installation positions:


Specific positioning: Each 6SY7000 part number corresponds to a defined position within a specific MASTERDRIVES drive chassis — the generator side, line side, or specific phase position within the inverter bridge.

Pre-matched specifications: Siemens ensures the FZ1800R16KF4 module in 6SY7000-0AD50 meets the thermal interface, mounting, and gate drive requirements of the MASTERDRIVES chassis it fits — eliminating compatibility uncertainty compared to sourcing a generic FZ1800R16KF4 from the Infineon catalogue.


Applications — High-Power Industrial Drives

At 1800A / 1600V, the 6SY7000-0AD50 serves the largest industrial drive applications:

Steel industry rolling mills: Hot and cold rolling mill main drive and auxiliary drives — with peak motor currents in the kiloamp range during billet rolling and tension control operations.

Paper and board machines: Large paper machine main drive systems requiring smooth variable speed control of motors in the multi-megawatt class.


Mining hoists: Deep mine shaft hoisting equipment — large motors, high torques, regenerative operation during lowering, and demanding duty cycles.

Wind turbine converters: Grid-side and generator-side inverter stages in multi-megawatt wind turbine power converters — where the 1600V blocking voltage accommodates higher DC link voltages used in high-voltage converter designs


FAQ

Q1: What is the difference between 6SY7000-0AD50 (1800A) and 6SY7000-0AC37 (1200A) in the same MASTERDRIVES system?

6SY7000-0AD50 (FZ1800R16KF4, 1800A) is the generator/motor-side inverter module in the highest-power MASTERDRIVES configurations. 6SY7000-0AC37 (FZ1200R16KF4, 1200A) is the line/supply-side module in regenerative MASTERDRIVES systems. The generator side typically carries higher peak current than the line side during motor overload events — hence the higher 1800A rating for the generator-side position.


Q2: Can 6SY7000-0AD50 be substituted with a directly sourced FZ1800R16KF4 from Infineon?

Technically, the 6SY7000-0AD50 uses the Infineon FZ1800R16KF4 as its core IGBT device. However, Siemens 6SY7000-series modules are pre-screened and catalogued for the specific MASTERDRIVES installation position. For SIMOVERT MASTERDRIVES warranty and service purposes, using the Siemens-catalogued 6SY7000-0AD50 is the correct approach. Direct Infineon FZ1800R16KF4 substitution is technically possible for experienced drive maintenance engineers who can verify thermal interface and mounting compatibility.


Q3: What safety precautions apply when replacing 6SY7000-0AD50 in a MASTERDRIVES chassis?

The SIMOVERT MASTERDRIVES DC bus at 1600V class retains hazardous voltage after mains isolation — follow the MASTERDRIVES maintenance manual's full discharge procedure and verify DC bus voltage is below 50V before accessing power stage components. At 1800A capability, these modules are physically large and heavy — both hands and appropriate ESD precautions are required. Follow Siemens' documented torque specifications for module mounting screws.


Q4: What symptoms indicate a failed 6SY7000-0AD50 IGBT module in a MASTERDRIVES installation?

Generator-side IGBT failures typically generate F030 hardware alarms indicating power module overcurrent, short circuit, or desaturation — appearing during drive enable or under load. Specific alarm codes reference the affected inverter bridge phase. Distinguish from control board faults (which produce parameter or communication errors) and from motor faults (which produce current asymmetry patterns). Confirm by resistance measurement of the IGBT junctions with the DC bus discharged.


Q5: What is the mounting and thermal interface specification for 6SY7000-0AD50?

FZ1800R16KF4 EconoPACK+ modules require a flat, clean heatsink surface with appropriate thermal interface compound (thermal grease or pad) and mounting torque per the Infineon FZ1800R16KF4 datasheet specification. Inadequate contact pressure or contaminated thermal interface significantly increases junction temperature under the same power dissipation — reducing module reliability and potentially causing premature failure. Follow the MASTERDRIVES chassis maintenance manual for the specific mounting torque and thermal compound specification.


Contact Us at Any Time

+86 18620505228
10/F,Jia Yue Building, Chebei Road,Tianhe district,Guangzhou ,China
Send your inquiry directly to us